> ## Documentation Index
> Fetch the complete documentation index at: https://vastai-80aa3a82-docs-host-network-maintenance.mintlify.site/llms.txt
> Use this file to discover all available pages before exploring further.

# Network Maintenance

> The routine network check for a host machine: line speed, link health, public IPv4, and the forwarded port range, plus the network changes that need a maintenance window.

Vast requires 500 Mbps down and up, wired Ethernet, a public IPv4 address that
is yours rather than shared, and 5 forwarded ports per GPU with 100 per GPU
recommended. See the [verification requirements](/host/verification-stages).

Networking drifts away from that without anything appearing to break. A cable
that renegotiated down, a reboot that moved your machine off the address your
router forwards to, a firmware update that re-entered a rule over a shorter
range: in each case the machine stays online, the daemon stays connected, and
it keeps taking rentals while quietly failing the requirement.

This page is for a machine that is up and drifting. For a machine that has
dropped off the platform entirely, start with
[Offline Machine](/host/machine-offline).

The steps are the same on Ubuntu Server 22.04 and 24.04.

<Note>
  Read the general checks, then the section matching your setup. One machine
  behind a router and a rack behind a shared uplink fail in different ways.
</Note>

<Warning>
  Most of the general checks read state rather than change it, but two are not
  free. Step 2 saturates your line while it measures, and step 6 can change the
  machine's address. Both need a maintenance window on a machine with rentals on
  it. Everything that interrupts is collected in
  [Changes that need a window](#changes-that-need-a-window).
</Warning>

***

## General checks

Run these on every machine you host, on whatever cadence you have settled on.
Most produce a number worth writing down, because what matters is this window's
number against your last one.

### 1. Find the interface

Everything below acts on the interface carrying the default route, so resolve
it once and let the later commands read it:

```bash theme={null}
NIC=$(ip -o route get 1.1.1.1 | grep -oP 'dev \K\S+'); echo "${NIC:?no default route found}"
```

```
enp1s0
```

Confirm it is a physical port rather than something layered on top of one:

```bash theme={null}
readlink -f /sys/class/net/"$NIC"
```

```
/sys/devices/pci0000:00/0000:00:01.2/0000:01:00.0/net/enp1s0
```

A path through `/devices/pci...` is a real NIC. If instead you get `$NIC` as a
bond, VLAN, bridge, or VPN tunnel (`bond0`, `enp1s0.100`, `wg0`, `tailscale0`),
it has no physical link of its own, and steps 3 and 4 have to be run against
each physical member interface instead. `ethtool` will happily report
`Duplex: Full` and `Link detected: yes` on a tunnel, so this is worth
confirming rather than assuming.

`NIC` lives only in the shell session you set it in. If your connection drops,
or you open a second terminal, set it again before continuing.

<Warning>
  If this resolves to a wireless interface, usually a name beginning `wl`, the
  machine is routing over Wi-Fi. Wired Ethernet is a requirement and a machine on
  Wi-Fi does not meet it, however fast the link tests. Move it back to Ethernet
  before going on.
</Warning>

### 2. Measure the line

Measure from the machine itself. A laptop on the same network takes a different
path through the switch, and on Wi-Fi it is not measuring your machine's link
at all.

<Warning>
  This drives the line to saturation for the length of the run, so anything a
  renter is transferring slows down while it happens. Run it when the machine is
  idle, or inside a window scheduled with
  [`vastai schedule maintenance`](/host/cli/schedule-maint).
</Warning>

```bash theme={null}
sudo apt-get update
sudo apt-get install -y speedtest-cli iperf3
```

```bash theme={null}
speedtest-cli --secure
```

```
Retrieving speedtest.net configuration...
Testing from Example ISP (198.51.100.7)...
Retrieving speedtest.net server list...
Selecting best server based on ping...
Hosted by Example Host (City) [12.34 km]: 8.129 ms
Testing download speed................................................................................
Download: 942.31 Mbit/s
Testing upload speed......................................................................................................
Upload: 918.44 Mbit/s
```

Both numbers must be at or above 500 Mbit/s. Upload is the one that fails
first: consumer and small-business lines are frequently sold asymmetric, and a
line advertised as 1 Gbps is often 1000 down and 50 up, which does not meet the
requirement however good the download figure looks.

Treat that result as one data point rather than the verdict. `speedtest-cli` is
an unmaintained Python client measuring over HTTP against a public server you
did not choose, so the figure moves with that server's load and the path to it.
On a fast line, confirm with `iperf3` against a public server:

```bash theme={null}
iperf3 -c <public iperf3 server hostname> -t 30 -P 4
iperf3 -c <public iperf3 server hostname> -t 30 -P 4 -R
```

The first run measures upload and the second download. Read the final
`[SUM]` line of each, the one marked `receiver`:

```
[SUM]   0.00-30.00  sec  3.28 GBytes   940 Mbits/sec                  receiver
```

Many public `iperf3` servers cap stream count and duration and listen on a
non-default port, so check the terms of whichever you pick.

Measure at a busy hour, not only at night. A line returning 900/900 at 03:00
and 300/150 at 20:00 fails the requirement for most of the day your renters are
actually using it.

### 3. Check the link itself

Your line can only be as fast as the link the NIC negotiated with whatever it
is plugged into:

```bash theme={null}
sudo ethtool "$NIC" | grep -E 'Speed|Duplex|Auto-negotiation|Link detected'
```

```
	Speed: 10000Mb/s
	Duplex: Full
	Auto-negotiation: on
	Link detected: yes
```

`Duplex: Full` and `Link detected: yes` are the only acceptable values on a
physical port. `Half` duplex collapses throughput under load and points at a
switch port that failed to negotiate.

`Speed` is the value to record and compare. It is not a fixed property of the
machine: a link renegotiates on every cable reseat, switch reboot, and port
move, and a marginal cable comes back at a lower speed rather than not at all.
A machine that reported `10000Mb/s` last window and reports `1000Mb/s` now has
a physical problem, even though every other check here will pass.

If the speed is lower than your hardware should manage, read the full output
and compare the supported modes against the advertised ones:

```bash theme={null}
sudo ethtool "$NIC"
```

A NIC that supports 10 Gb but advertises only 1 Gb has usually been pinned by
an `ethtool -s` command run by hand or from a systemd unit, a udev rule, or a
systemd-networkd `[Link]` section. Netplan has no key for link speed, so there
is no point looking for one in your YAML. A NIC that supports 10 Gb where the
link partner does not is a switch port or transceiver question.

On a fibre link, read the transceiver's own diagnostics as well. Optical
receive power falling window over window is the classic months-long
degradation, and it shows up here before it shows up anywhere else:

```bash theme={null}
sudo ethtool -m "$NIC"
```

### 4. Read the error counters

This is the check that finds a failing cable before it takes the machine down,
and a single reading is worthless. Counters are cumulative since boot, so the
number alone means nothing; the number against last window's, over a known
number of days, is the signal.

The Network tab in [Machine Metrics](/host/machine-metrics) already charts RX
and TX errors and drops per machine, sampled rather than accumulated, so a
healthy interface reads a flat zero and anything above it stands out without
any arithmetic on your part. Read the trend there first. The commands below are
the point-in-time confirmation on the machine itself.

```bash theme={null}
sudo ethtool -S "$NIC" | grep -iE 'err|drop|discard|crc|fail' | grep -v ': 0$'
```

Empty output does not by itself mean the interface is clean, because it also
looks exactly like a NIC whose driver exposes no statistics or names its
counters outside those words. Confirm the counters exist, and read the generic
ones the kernel keeps for every interface:

```bash theme={null}
sudo ethtool -S "$NIC" | wc -l
ip -s -s link show "$NIC"
```

A count of `1`, or `no stats available`, means this driver has nothing to
offer and `ip -s -s link` is your only source. Record whatever either prints:

```
     rx_crc_errors: 1847
     rx_missed_errors: 293
```

Non-zero is not automatically a fault. Plenty of drivers carry a small standing
count that never moves. `rx_crc_errors` climbing means frames are arriving
corrupted, which is a cabling, transceiver, or switch port fault rather than a
software one. `rx_missed_errors` means the NIC received frames it had no buffer
for, which points at the machine rather than the cable.

Take the uptime alongside it, so your next window can work out a rate:

```bash theme={null}
uptime -p
```

<Note>
  A count that has not moved since last window is fine however large it is. A
  machine that logged 2,000 CRC errors during a switch replacement months ago and
  none since has a clean link. One adding to the count steadily does not, and it
  reaches your renters as slow transfers long before it reaches you as a failure.
</Note>

### 5. Confirm the public IPv4 address

```bash theme={null}
curl -4 -s ifconfig.me; echo
```

```
198.51.100.7
```

The maintenance question is whether this has changed since your last window. If
it has, update everything pinned to the old value: dynamic DNS, and any router
rule written against a specific WAN address.

<Note>
  How the platform picks up a changed address is part of machine setup rather
  than maintenance. See the
  [host setup guide](https://cloud.vast.ai/host/setup/).
</Note>

Then compare the address against the WAN address your router reports. They must match.
If your router's WAN interface holds a different address, something between you
and the internet is doing NAT you do not control, and renters cannot be
forwarded through it. That comparison is the general test, and it catches every
shared-address case, including the ones that do not use a recognizable range.

<Warning>
  A router WAN address inside `100.64.0.0/10` means your ISP has put the
  connection behind carrier-grade NAT. Ports cannot be forwarded through it, and
  [the requirements](/host/verification-stages) exclude both CGNAT and a shared
  ISP address from hosting. ISPs migrate existing customers onto CGNAT without
  announcing it, so this is worth re-checking rather than treating as settled at
  setup.
</Warning>

<Note>
  Sharing one public address across several of your own machines is a different
  thing and is fine, as long as each machine has its own forwarded range. See
  [Allocate non-overlapping port ranges](#3-allocate-non-overlapping-port-ranges).
</Note>

### 6. Pin the machine to one LAN address

Your router forwards the port range to a LAN address. If the machine's address
moves, the rule points at whatever else picked it up, or at nothing.

```bash theme={null}
sudo grep -rE 'dhcp4|addresses' /etc/netplan/
```

```
/etc/netplan/00-installer-config.yaml:      dhcp4: true
```

The `sudo` is not optional. On 24.04 the netplan files are root-only, and an
unprivileged `grep` prints permission errors to stderr and no matches to
stdout, which reads exactly like a machine that is already static.

`dhcp4: true` means the address is a lease, and a lease is not a promise. It
usually survives a reboot, and then one day it does not: the machine is off
long enough for the lease to expire during a drive replacement, the router
rebuilds its lease table, or another device claims the address first. The
machine comes back healthy on a new address with your forwarding rule pointing
at the old one. Every other maintenance page ends in a reboot, which is what
makes this worth checking rather than assuming.

Fix it in one of two places. Prefer a DHCP reservation on your router, keyed to
the machine's MAC address: your forwarding rule and the address it points at
then live in the same place, and the machine still boots correctly if you swap
it out.

```bash theme={null}
cat /sys/class/net/"$NIC"/address
```

```
3c:ec:ef:1a:2b:3c
```

A static address in netplan also works and is the better choice if your
router's DHCP server is unreliable. Set it outside the DHCP pool so nothing
else is ever handed the same address, and on a cloud-init managed server write
`/etc/cloud/cloud.cfg.d/99-disable-network-config.cfg` as well, or cloud-init
regenerates `50-cloud-init.yaml` on the next boot and undoes the change.

<Warning>
  Changing the address drops your SSH session and the daemon's connection to
  Vast. Do it inside a window scheduled with
  [`vastai schedule maintenance`](/host/cli/schedule-maint), and see
  [Applying a netplan change without locking yourself out](#applying-a-netplan-change-without-locking-yourself-out).
</Warning>

### 7. Size the port range against the GPU count

The number of ports the machine needs is a function of how many GPUs are in it,
so it changes whenever your hardware does.

```bash theme={null}
nvidia-smi --query-gpu=name --format=csv,noheader | wc -l
```

```
8
```

A result of `0` means `nvidia-smi` failed rather than that the machine has no
GPUs; the error goes to stderr and `wc -l` counts nothing.

<Note>
  **Formula for verification:** forwarded ports >= 5 x number of GPUs, with
  100 x number of GPUs recommended

  **Example:** 8 GPUs means at least 40 forwarded ports to qualify for
  verification, and 800 recommended
</Note>

| GPUs | Minimum for verification | Recommended |
| ---- | ------------------------ | ----------- |
| 1    | 5                        | 100         |
| 2    | 10                       | 200         |
| 4    | 20                       | 400         |
| 8    | 40                       | 800         |

Compare that against the range you have forwarded on your router. If you have
added GPUs since setup, the machine is running on a range sized for the
hardware it used to have. Nothing reports this as an error; the machine simply
takes fewer rentals and loses the ones needing many ports.

The **Ports** value on the machine's card under **Host → Machines** in the
console is what the platform believes the machine offers, so check your
arithmetic against it. A machine showing no port data there has not reported a
usable range at all, which [How to Self-Test](/host/how-to-self-test) lists as
something to fix before the self-test will run.

Resizing a range is two changes, not one. Widening the rule on your router is
the first; telling the platform its new range is the second, which the
[host setup guide](https://cloud.vast.ai/host/setup/) covers.

<Warning>
  Changing the range moves instances that were mapped into the old one. Do it
  inside a window scheduled with
  [`vastai schedule maintenance`](/host/cli/schedule-maint).
</Warning>

### 8. Check the firewall and the ephemeral port range

Two host-side settings can break a range your router is forwarding perfectly.

```bash theme={null}
sudo ufw status verbose
```

`ufw` is Ubuntu's default firewall tool and is present on a server install, but
it ships disabled. A machine where you have never turned it on reports:

```
Status: inactive
```

That is a valid answer here. An inactive firewall is not blocking your range,
so it is not a candidate when the port test in step 9 fails, and there is
nothing further to check in this half of the step.

Where you have enabled it, read the rules:

```
Status: active
Logging: on (low)
Default: deny (incoming), allow (outgoing), disabled (routed)
New profiles: skip

To                         Action      From
--                         ------      ----
22/tcp                     ALLOW IN    Anywhere
61000:61799/tcp            ALLOW IN    Anywhere
61000:61799/udp            ALLOW IN    Anywhere
```

<Warning>
  Allow SSH before you enable or reload `ufw`. Run `sudo ufw allow 22/tcp` first:
  enabling a default-deny firewall without it ends your session, and the recovery
  is a trip to the machine or its BMC. Whatever else you change, your range must
  stay reachable and the daemon's outbound connection must stay open.
  `Default: allow (outgoing)` above is what keeps the daemon able to reach the
  Vast controller, and a default deny outbound takes the machine offline with
  every inbound rule still correct.
</Warning>

Now check that your range does not sit inside the range the kernel hands out
for outbound connections:

```bash theme={null}
sysctl net.ipv4.ip_local_port_range
```

```
net.ipv4.ip_local_port_range = 32768	60999
```

A forwarded range overlapping this one is a slow, density-dependent failure: an
outbound connection from the machine can take a port an instance later needs to
bind, so rentals fail to start intermittently while every check on this page
passes. Keep your range clear of it, on either side, or reserve it with
`net.ipv4.ip_local_reserved_ports`.

<Note>
  Instances are Docker containers, and Docker publishes their ports through its
  own chains rather than through `ufw`, so a `deny (incoming)` default does not
  close them. To restrict the Vast range at the host, use the `DOCKER-USER`
  chain, which Docker leaves alone:

  ```bash theme={null}
  sudo iptables -t nat -S DOCKER
  sudo iptables -S DOCKER-USER
  ```
</Note>

`ufw` rules persist across a reboot. Rules added by hand with `iptables` do
not, unless something restores them:

```bash theme={null}
sudo iptables -S
dpkg -l | grep -E 'iptables-persistent|netfilter-persistent'
```

Ignore the `DOCKER`, `DOCKER-USER`, and `DOCKER-ISOLATION` chains in that
output; dockerd rebuilds those itself at boot. Only rules you added by hand are
at risk, and the fix for those is to move them into `ufw`.

<Warning>
  Do not run `netfilter-persistent save` on a machine running instances. It
  snapshots the container rules dockerd created, and restoring them at boot
  before dockerd starts breaks instance port mapping.
</Warning>

### 9. Test both ends of the range from outside

Testing one port in the middle of your range is the check that misses the
failure this step exists for. A rule re-entered after a firmware update over a
shorter range than you configured still passes that test and leaves the rest of
the range dead.

You do not have to test every port. Where your range is one forwarding rule,
the lowest and the highest port tell you whether the whole thing arrives, and
the highest is the one that matters: a rule truncated at the top end is the
common failure, and every renter landing on the working part has a normal
experience.

If your router made you enter the range as several rules, test the first and
last port of each of them.

Test from **outside** your network, on a VPS, a phone hotspot, or anything on a
different connection. Running it from inside your LAN tells you nothing,
because your router may answer its own public address differently than the
internet does.

On the machine, start a listener on the lowest port in your range:

```bash theme={null}
nc -l <lowest port in your range>
```

From your outside connection:

```bash theme={null}
nc -v <your public IPv4 address> <lowest port in your range>
```

```
Connection to 198.51.100.7 61000 port [tcp/*] succeeded!
```

Type a line and press enter. It appears in the listener on the machine, which
is what proves the connection arrived rather than being answered by something
in between. Press Ctrl-C at both ends.

That covers TCP. Repeat both commands with `-u` to prove UDP arrives too, since
renters can [map UDP ports](/guides/instances/connect/networking) as well:

```bash theme={null}
nc -u -l <lowest port in your range>
```

```bash theme={null}
nc -u -v <your public IPv4 address> <lowest port in your range>
```

UDP has no handshake to succeed, so the only proof is the line you type
appearing in the listener.

Now run all of it again with the **highest** port in your range.

<Warning>
  Run the listener as your normal user, never with `sudo`, and never on a port an
  instance is currently using. `nc` sets `SO_REUSEPORT`, so a root-owned listener
  binds alongside the instance already on that port and takes a share of that
  renter's incoming connections rather than failing.
</Warning>

<Note>
  If `ufw` is active, this test goes through it, because the listener is an
  ordinary host socket. A range blocked in `ufw` fails here even though instance
  ports on the same range would work, since Docker publishes those through its
  own chains. That is why step 8 comes first.
</Note>

### 10. Check for loss and DNS drift

A machine passing every check above can still be unreliable if the path to it
drops packets.

```bash theme={null}
ping -c 100 -i 0.2 1.1.1.1 | tail -3
```

```
--- 1.1.1.1 ping statistics ---
100 packets transmitted, 100 received, 0% packet loss, time 19898ms
rtt min/avg/max/mdev = 8.104/8.393/9.221/0.184 ms
```

`0% packet loss` is the expected result, and any sustained loss is worth
chasing: it costs far more throughput than its percentage suggests, because
every lost segment is a retransmit and a congestion-window cut. A high `mdev`
is jitter, which renters notice on interactive sessions first.

Where the loss happens matters more than that it happens:

```bash theme={null}
sudo apt-get install -y mtr-tiny
mtr -r -c 100 1.1.1.1
```

```
HOST: gpu-01                      Loss%   Snt   Last   Avg  Best  Wrst StDev
  1.|-- 192.168.1.1                0.0%   100    0.4   0.5   0.3   1.2   0.1
  2.|-- 203.0.113.9               12.0%   100    9.1   9.4   8.7  18.2   1.3
  3.|-- 203.0.113.1                0.0%   100    8.9   9.2   8.6  15.1   0.9
  4.|-- 1.1.1.1                    0.0%   100    8.4   8.6   8.1  11.9   0.6
```

Loss at an intermediate hop that does not carry through to the last line, as at
hop 2 here, is that router deprioritizing its own ICMP replies. It is not
affecting traffic, and it is the most common false alarm in this check. Loss
appearing at a hop and persisting to the final hop is real.

For DNS, the question is not whether resolution works right now but whether it
depends on a single resolver that can take the machine offline on its own:

```bash theme={null}
resolvectl status "$NIC"
```

```
Link 2 (enp1s0)
    Current Scopes: DNS
         Protocols: +DefaultRoute +LLMNR -mDNS -DNSOverTLS DNSSEC=no/unsupported
Current DNS Server: 192.168.1.1
       DNS Servers: 192.168.1.1
```

One entry under `DNS Servers` is a single point of failure, and that entry is
usually your router. The daemon reaches the Vast controller by name, so a
router reboot or a flapping upstream resolver takes the machine offline while
your line is working perfectly. Add a second resolver, such as `1.1.1.1` or
`8.8.8.8`, so the machine keeps resolving when the first stops answering.

<Note>
  If this shows no DNS servers while resolution plainly works, the machine has a
  hand-written `/etc/resolv.conf` bypassing `systemd-resolved`. Read that file
  instead.
</Note>

Resolution failing outright is covered by
[Offline Machine](/host/machine-offline).

<Check>
  `speedtest-cli` at or above 500 Mbit/s both ways, `ethtool` reporting the speed
  you expect at full duplex, no error counter moving since your last window, your
  public address unchanged and matching your router's WAN address, your LAN
  address pinned, your range clear of the ephemeral range with the firewall rules
  surviving a reboot, both ends of the range answering over TCP and UDP from
  outside, and no sustained loss to the final hop. Record the speeds, the link
  speed, the error counts, your public address, and the date.

  For the platform's own verdict on the same ground, run
  [`vastai self-test machine`](/host/cli/self-test-machine) while the machine is
  idle. It checks network speed, stability, and open ports directly.
</Check>

***

## Single-machine hosts

One machine behind one router. Almost everything that drifts here drifts on the
router rather than on the machine, so if you only ever log into the machine,
you never see it coming.

### 1. Re-verify the range after any router work

Firmware updates, factory resets, and configuration restores all lose or
rewrite forwarding rules, and consumer routers rarely tell you they have. Treat
any router work as a change to the machine and re-run
[the port test](#9-test-both-ends-of-the-range-from-outside) afterwards.

The same applies to a rule still listed that no longer works. Check that its
destination address still matches the machine, that it covers both TCP and UDP,
and that its range matches what you sized in
[step 7](#7-size-the-port-range-against-the-gpu-count).

<Warning>
  Re-entering rules or rebooting the router drops the machine off the network and
  stops every running instance. Schedule it with
  [`vastai schedule maintenance`](/host/cli/schedule-maint).
</Warning>

### 2. Check the router is not the bottleneck

Your router can pass a speed test and still cap the machine, because a speed
test opens a handful of connections and a busy machine opens thousands. The
symptom is a line measuring at full speed while renters report slow or stalled
connections during busy periods.

Consumer routers have a finite NAT connection table, and the recommended 100
ports per GPU is a lot of concurrent state for a small device. If yours exposes
a connection count or NAT table size, record it during a busy period alongside
the rest of this check. A router at its limit drops new connections while
existing ones keep working, which is what makes it hard to catch.

The machine keeps its own table, and it fills the same way as rental density
grows:

```bash theme={null}
sysctl net.netfilter.nf_conntrack_count net.netfilter.nf_conntrack_max
```

The maximum is derived from installed RAM, so read yours rather than comparing
against a published figure. A count approaching it puts
`nf_conntrack: table full, dropping packet` in `dmesg`.

The same class of limit applies to the forwarding rules themselves. Some
routers cap the number of entries, and some cannot express a large contiguous
range at all and want it entered as many individual rules. Both bite at the
recommended port count rather than the minimum, so check what yours can express
before sizing a range around 100 ports per GPU.

***

## Multi-machine hosts on one network

Once there is more than one machine behind the same uplink, capacity is shared
and the requirement is per machine. Everything here is about what the fleet
does to itself, and it gets worse as the fleet grows without any individual
machine changing.

### 1. Measure the uplink under load

A machine tested on an otherwise idle network tells you nothing about what it
delivers when its neighbors are busy. The requirement is 500 Mbps each way for
each machine, at the same time.

<Note>
  **Derived from the per-machine requirement**, not a published Vast figure:
  uplink >= 500 Mbps x number of machines, in each direction. Six machines need
  3 Gbps symmetric, sustained.
</Note>

Measure it rather than assuming. Run this on every machine at once, from
separate terminals:

```bash theme={null}
iperf3 -c <public iperf3 server hostname> -t 30 -P 4
```

Then run the download direction with `-R`, and add the final `[SUM]` figures
across all the machines. A total that stops rising as you add machines is the
uplink saturating, and every machine on it is below requirement at that moment
regardless of what each measured alone.

<Warning>
  This saturates the uplink for the length of the run, which affects renters on
  every machine and anything else on the network. Schedule it with
  [`vastai schedule maintenance`](/host/cli/schedule-maint) on each machine.
</Warning>

### 2. Check the switch uplink, not just the ISP line

The most common capacity fault in a multi-machine setup is not the ISP link. It
is the single cable between the switch your machines are plugged into and the
router.

Eight machines on 1 Gb access ports feeding one 1 Gb uplink gives the whole
fleet 1 Gb to share, about 125 Mbps each under full load, on an internet
connection measuring 10 Gb all day from any single machine.

Test the fabric directly rather than through the internet. On one machine:

```bash theme={null}
sudo ufw allow from <your LAN subnet> to any port 5201 proto tcp
iperf3 -s
```

The `ufw` rule is needed because `iperf3 -s` listens on an ordinary host socket
that a `deny (incoming)` default drops, and the client then just times out with
no indication why. Remove it when you are done.

On another machine:

```bash theme={null}
iperf3 -c <the listening machine's LAN address> -t 30 -P 4
```

```
[SUM]   0.00-30.00  sec  3.28 GBytes   940 Mbits/sec                  receiver
```

Two machines on gigabit ports should reach roughly 940 Mbit/s between them,
which is the practical TCP ceiling on a 1 Gb link once framing overhead is
taken out. Substantially less means the switch, the cabling, or a port is the
limit, and no amount of ISP bandwidth will help. Run
[the link](#3-check-the-link-itself) and
[counter](#4-read-the-error-counters) checks on every machine, not just the one
complaining: a single machine with a marginal cable pushes retransmits through
a shared switch and slows its neighbors.

### 3. Allocate non-overlapping port ranges

Machines behind one public IPv4 address share one port space. Each needs its
own range, sized to its own GPU count, and the ranges must not overlap.

Work it out per machine before you touch the router. For a fleet of three, one
with 8 GPUs, one with 4, and one with 8, the arithmetic from
[step 7](#7-size-the-port-range-against-the-gpu-count) gives 800, 400, and 800
ports at the recommended count: 2,000 ports in total, as three non-overlapping
ranges, each of which is itself contiguous. Leave gaps between them if you
expect GPU counts to change, because growing a range into one another machine
is using is an outage for both.

Keep the range, the machine, and its LAN address written down together. Your
router only shows you the first and last of those three. Watch the ceiling as
the fleet grows: one address has 65,535 ports, the ephemeral range claims
roughly 28,000 of them by default, and at 800 ports per 8-GPU machine that runs
out sooner than it looks.

Verify each range with
[the port test](#9-test-both-ends-of-the-range-from-outside), run once per
machine against that machine's own lowest and highest port.

That proves each range is forwarded. It does not prove each reaches the *right*
machine, and adjacent ranges typed into a router are exactly where that goes
wrong. Confirm the destination for at least one port per machine. On the
machine:

```bash theme={null}
nc -l <an unused port from that machine's range>
```

From outside your network:

```bash theme={null}
nc -v <your public IPv4 address> <the same port>
```

Anything you type appears on the machine you started the listener on. If it
appears on a different machine, two rules have been transposed.

### 4. Size the shared infrastructure for the fleet

Three limits on shared equipment scale with machine count and quietly stop
being adequate:

* **The DHCP pool.** Large enough for every machine plus everything else on the
  network, with a reservation for each so that
  [pinned addresses](#6-pin-the-machine-to-one-lan-address) hold across the
  fleet.
* **The connection tracking table** on the router. Every renter connection to
  every machine is an entry, and this is the limit that turns into fleet-wide
  connection failures during busy periods while each machine looks healthy.
* **Bandwidth fairness.** Nothing stops one machine saturating the shared line
  and pushing the others below 500 Mbps. If your router supports per-client
  rate limiting, cap each machine at its share.

### 5. Treat adding a machine as maintenance on all of them

Adding a machine divides the uplink again, consumes another block of the shared
port space, and adds load to the router's connection table. The new machine is
the one being installed; the existing machines are the ones that change
behavior.

Afterwards, re-run [the uplink measurement](#1-measure-the-uplink-under-load)
across the whole fleet and confirm the new range overlaps nothing.

<Warning>
  A router or switch reboot takes every machine behind it offline at once, not
  just the one you are working on. Firmware updates, configuration restores, and
  moving a machine between switch ports all count. Schedule the window on
  **every** affected machine with
  [`vastai schedule maintenance`](/host/cli/schedule-maint) before starting, and
  wait until no machine in the fleet has an active rental contract running
  through it.
</Warning>

***

## Changes that need a window

Most of this page reads state. These are the changes it leads to, and all of
them interrupt rentals. Schedule them with
[`vastai schedule maintenance`](/host/cli/schedule-maint).

| Change                                              | What it interrupts                                 |
| --------------------------------------------------- | -------------------------------------------------- |
| Measuring the line with `speedtest-cli` or `iperf3` | Transfers for every renter on the machine          |
| Changing the machine's LAN address                  | SSH, the daemon connection, every running instance |
| Applying any netplan change                         | The machine's networking, briefly                  |
| Enabling or reloading `ufw`                         | Your own session, if SSH is not allowed first      |
| Changing the forwarded port range                   | Instances mapped into the old range                |
| Replacing a cable or moving a switch port           | That machine                                       |
| Router or switch firmware update or reboot          | Every machine behind it                            |

### Applying a netplan change without locking yourself out

A wrong netplan file applied over SSH leaves an unreachable machine, and the
recovery is a trip to the machine or its BMC. `netplan try` exists for this: it
applies the configuration, waits, and rolls back automatically unless you
confirm at the console.

```bash theme={null}
sudo netplan try
```

```
Do you want to keep these settings?

Press ENTER before the timeout to accept the new configuration

Changes will revert in 120 seconds
```

If the change breaks your connection you cannot press ENTER, the timeout
expires, and the machine reverts to what was working. Pressing ENTER keeps the
configuration, which is already applied at that point, so there is nothing
further to run.

<Warning>
  `netplan try` cannot protect a bonded or bridged configuration with custom
  parameters. It exits before applying anything with
  `reverting custom parameters for bridges and bonds is not supported`. Apply
  that one from the console or over the BMC, not over SSH.
</Warning>

<Note>
  Changing the address means your existing session is connected to the old one.
  Open a session against the new address before closing the old one, and keep the
  old one open until the new one works.
</Note>

***

## Recovery

### Neither end of the range connects

Your rule is not delivering traffic to the machine at all. In order of
likelihood: the rule was lost by a router firmware update or reset; it points
at a LAN address the machine no longer holds, which is
[the DHCP problem](#6-pin-the-machine-to-one-lan-address); it covers TCP where
your range needs UDP too; or `ufw` is blocking the listener, which
[step 8](#8-check-the-firewall-and-the-ephemeral-port-range) will show.

Re-enter the rule, confirm its destination matches what
`ip -4 -brief addr show "$NIC"` reports, and test again.

<Warning>
  Re-entering a forwarding rule is a router change and can drop the machine.
  Schedule it with
  [`vastai schedule maintenance`](/host/cli/schedule-maint).
</Warning>

### The lowest port connects but the highest does not

Your router is forwarding a narrower range than you sized. Open the rule and
read the range it actually contains: that tells you directly whether it was
truncated or was never as wide as you thought, without probing the range from
outside. Widen it against the arithmetic in
[step 7](#7-size-the-port-range-against-the-gpu-count), then re-test the new
highest port.

If you run several machines on one network, confirm the widened range does not
run into the next machine's allocation before you apply it.

### The link renegotiated to a lower speed

This is physical. Reseat the cable at both ends, and if the speed does not come
back, move the machine to a different switch port to establish which end is at
fault. A cable that worked for a year and now negotiates at a tenth of its
rated speed is failing rather than failed, and it will keep getting worse.

<Warning>
  Reseating a cable or moving a switch port drops the machine off the network and
  stops every running instance. Schedule it with
  [`vastai schedule maintenance`](/host/cli/schedule-maint).
</Warning>

### Error counters are climbing

Note the count and the uptime, then check again a day later to establish a rate
before doing anything physical. A climbing rate follows the same path as the
section above: cable first, then port, then transceiver on fibre or DAC links.
Replace one thing at a time and re-measure, because replacing all three at once
tells you nothing about which was at fault.

### Bandwidth is below requirement and nothing on the machine is wrong

Establish where the ceiling is before contacting anyone. If two machines cannot
reach line rate between themselves on the LAN, it is the switch or the cabling
and it is yours to fix. If the LAN is clean and the uplink saturates below what
the fleet needs, work out whether the sum of what your machines need exceeds
what the line was sold to deliver, using
[the uplink arithmetic](#1-measure-the-uplink-under-load). Only once the